Feedback
 
Did this article resolve your question/issue?

   

Your feedback is appreciated.

Please tell us how we can make this article more useful. Please provide us a way to contact you, should we need clarification on the feedback provided or if you need further assistance.

Characters Remaining: 1025

 


Article

Error S1090 Seen When Connecting to DB2 on Windows NT

« Go Back

Information

 
Article Number000001439
EnvironmentWindows NT
IBM DB2 Database
ODBC DataServer 9.x
Question/Problem Description
Error when using the IBM ODBC driver
S1090: [Microsoft][ODBC Driver Manager]Invalid string or buffer lengthS1090: [Microsoft][ODBC Driver Manager]Function sequence error
Steps to Reproduce
Clarifying Information
Error Message
Defect/Enhancement Number
Cause
In the data-owning region (DOR) for DB2 on NT, asynchronous mode is enabled within the IBM DB2 ODBC driver.
Resolution
To disable asynchronous mode, add the following parameter to the DB2 connection parameters: -Dsrv ASYNC_ENABLE,0
Workaround
Notes
The fix does not apply to the Merant Driver
DataServer for ODBC Guide, Chapter 4, "Connecting the DataServer."
Attachment 