Feedback
 
Did this article resolve your question/issue?

   

Your feedback is appreciated.

Please tell us how we can make this article more useful. Please provide us a way to contact you, should we need clarification on the feedback provided or if you need further assistance.

Characters Remaining: 1025

 


Article

Service Pack installer does not install correct file versions for a FULL install

« Go Back

Information

 
Article Number000093895
EnvironmentProduct: OpenEdge
Version: 11.7.4, 11.7.5
OS: Windows
Other: Installation
Question/Problem Description
Service pack installer does not install correct file versions for FULL install.

A new Installation of 11.7.4 or 11.7.5 installs old PL-Files

Service Pack installer does not install correct versions of procedure libraries (.PL) when performing a FULL installation of OpenEdge 11.7.

Problem affects such files as:

gui\OpenEdge.Core.pl
gui\OpenEdge.BusinessLogic.pl
gui\OpenEdge.ServerAdmin.pl
gui\netlib\OpenEdge.Net.pl
gui\rules\OpenEdge.BusinessRules.pl
oeide\eclipse\plugins\org.apache.ant_1.9.6.v201510161327\bin\antRun.pl
oeide\eclipse\plugins\org.apache.ant_1.9.6.v201510161327\bin\complete-ant-cmd.pl
oeide\eclipse\plugins\org.apache.ant_1.9.6.v201510161327\bin\runant.pl
proedit\builtins\builtins.pl
tty\ablunit.pl

Installing a full OpenEdge 11.7 version with the 11.7.4 or 11.7.5 Service Pack installer.
Post install a variety of problems when running code relating to one or more of these procedure libraries.

Problem #1
After installing a full copy of 11.7.4, running the following code raises error 12927:
USING OpenEdge.Net.HTTP.IHttpRequest.
USING OpenEdge.Net.HTTP.IHttpResponse.
USING OpenEdge.Net.HTTP.ClientBuilder.
USING OpenEdge.Net.HTTP.RequestBuilder.
USING OpenEdge.Net.HTTP.IHttpClientLibrary.
USING OpenEdge.Net.HTTP.Lib.ClientLibraryBuilder.

DEFINE VARIABLE oLib AS IHttpClientLibrary NO-UNDO.
DEFINE VARIABLE oRequest  AS IHttpRequest NO-UNDO.
DEFINE VARIABLE oResponse AS IHttpResponse NO-UNDO.

ASSIGN
    oLib        = ClientLibraryBuilder:Build()
                                      :sslVerifyHost(NO)
                                      :ServerNameIndicator('some.servername.com')
                                      :library.                                                      
oRequest = RequestBuilder:Get('https://some.servername.com/'):Request.
oResponse = ClientBuilder:Build()
                         :UsingLibrary(oLib)
                         :Client
                         :Execute(oRequest).
                           
MESSAGE oResponse:StatusCode SKIP oResponse:StatusReason SKIP VIEW-AS ALERT-BOX.
The definition of the ConfigOption TEMP-TABLE changes between 11.7.0 and 11.7.4:
 
User-added image

The ServerNameIndicator method cannot be found in the Class Browser in the OpenEdge.Net.HTTP.Lib.ClientLibraryBuilder class:
User-added image

Problem #2
Running the following code fails with errors 13203 (relating to TEMP-TABLE ConfigOption definitions), 10068, 3135 as a result of the wrong version of gui\OpenEdge.Core.pl being present:
USING OpenEdge.Net.HTTP.IHttpClientLibrary.
USING OpenEdge.Net.HTTP.Lib.ClientLibraryBuilder.
USING OpenEdge.Net.HTTP.IHttpClient.
USING OpenEdge.Net.HTTP.IHttpRequest.
USING OpenEdge.Net.HTTP.IHttpResponse.
USING OpenEdge.Net.HTTP.RequestBuilder.
USING OpenEdge.Net.HTTP.ClientBuilder.

USING OpenEdge.Net.URI.
USING Progress.Lang.Object.
USING Progress.Json.ObjectModel.JsonObject.

DEFINE VARIABLE oURI                AS URI                  NO-UNDO.
DEFINE VARIABLE AuthObj             AS Progress.Json.ObjectModel.JsonObject  NO-UNDO.
DEFINE VARIABLE oRequest            AS IHttpRequest         NO-UNDO.
DEFINE VARIABLE oResponse           AS IHttpResponse        NO-UNDO.
DEFINE VARIABLE oLib                AS IHttpClientLibrary   NO-UNDO.

AuthObj = NEW JsonObject().

oLib = ClientLibraryBuilder:Build():AddSslProtocol('TLSv1.2'):Library.
oURI = new URI("http", "www.google.com").

oRequest = RequestBuilder:Post(oURI,AuthObj):acceptJson():Request.
oResponse = ClientBuilder:Build():Client:EXECUTE(oRequest).
MESSAGE "Finished"
    VIEW-AS ALERT-BOX INFORMATION BUTTONS OK.

The definition of the ConfigOption TEMP-TABLE changes between 11.7.0 and 11.7.4.
 
Steps to ReproducePerform a FULL product installation from the OpenEdge 11.7.4 or 11.7.5 Service pack installer.
Clarifying Information
Installing Openedge 11.7 with the FCS or a full install with earlier Service Packs does not have this problem.

Differences can be seen when comparing file versions with an OpenEdge 11.7.4 installation where OpenEdge 11.7 was previously installed from an earlier release and 11.7.4 was installed as a Service Pack update to the initial install.  

Properties from a FULL installation performed by the 11.7.4 service pack installer:
User-added image
 

 

Error MessageProblem #1
Could not locate element 'ServerNameIndicator' in class 'OpenEdge.Net.HTTP.Lib.ClientLibraryBuilder'. (12927) 
** Could not understand line 41. (196) 

Problem #2
TEMP-TABLE 'ConfigOption' of class 'OpenEdge.Net.HTTP.Lib.ClientLibraryBuilder' no longer matches the definition in base class 'OpenEdge.Core.Util.ConfigBuilder'. (13203)
TEMP-TABLE 'ConfigOption' of class 'OpenEdge.Net.HTTP.ConfigBuilder' no longer matches the definition in base class 'OpenEdge.Core.Util.ConfigBuilder'. (13203)
TEMP-TABLE 'ConfigOption' of class 'OpenEdge.Net.HTTP.Lib.ClientLibraryBuilder' no longer matches the definition in base class 'OpenEdge.Core.Util.ConfigBuilder'. (13203)
TEMP-TABLE 'ConfigOption' of class 'OpenEdge.Net.HTTP.Lib.ABLSockets.ABLSocketLibraryBuilder' no longer matches the definition in base class 'OpenEdge.Core.Util.ConfigBuilder'. (13203)
TEMP-TABLE 'ConfigOption' of class 'OpenEdge.Logging.LoggerBuilder' no longer matches the definition in base class 'OpenEdge.Core.Util.ConfigBuilder'. (13203)
Lead attributes in a chained-attribute expression (a:b:c) must be type HANDLE or a user-defined type and valid (not UNKNOWN). (10068)
Invalid handle. Not initialized or points to a deleted object. (3135)
Defect/Enhancement NumberDefect ADAS-13620
Cause
The Service Pack installation completes successfully, but some of the library file versions that were updated since 11.7.4 are not correct. The problem is not immediately obvious and can only be seen by running code or by comparing file versions with a valid installation.  
Resolution
None at this time. Until the fix is available, use the workaround below.
Workaround
Option 1:  Re-install the Service Pack

After installing the 11.7 Service Pack as the Full install, re-install the service pack from the service pack installer. The correct files are installed in the second run because the 11.7 Service Pack is then found and only re-installs the SP content.

1.  Answer 'No'  - to re-install the Service Pack:
--------------------------- 
Question 
--------------------------- 
This service pack has already been installed. 
Would you like to add products to the existing installation? 

Choose Yes to add additional products to this installation. 
Choose No to re-apply the service pack to this installation. 
--------------------------- 
Yes No 
--------------------------- 

2.  Answer 'Yes'  - to confirm reinstalling the Service Pack
--------------------------- 
Question 
--------------------------- 
OpenEdge r11.7 already has Service Pack 4 installed. 

Would you like to proceed with this reinstall of Service Pack 4? 

Click "No" to exit. 
--------------------------- 
Yes No 
--------------------------- 

Once the Service Pack is re-installed, the correct version of these procedure library files resolving the problem:
    
User-added image

User-added image

Option 2:  Replace the Full Service Pack Install procedure libraries

Include the required procedure libraries as part of application code deployment, or added these as a "post-install batch" to copy the needed libraries to the full SP install.
Notes
Attachment 
Last Modified Date12/6/2019 3:55 PM