Unable to run PROUTIL increaseto error 13984

« Go Back

Information

 
TitleUnable to run PROUTIL increaseto error 13984
URL Name000065996
Article Number000183705
EnvironmentProduct: OpenEdge
Version: 10.1C, 10.2x, 11.x
OS: All supported platforms
Question/Problem Description
Increasing parameter values online with PROUTIL increaseto fails with error 13984
Increasing database server startup parameters online fails with error 13984
Steps to Reproduce
Clarifying Information
Multiple server startup parameters are being increased at the same time.
Server startup parameters are valid for the PROUTIL increaseto function.
User increasing parameters has Security privileges on the directly connected database
Error MessageIncrease Params no valid increase online parameter specified. (13984)
Defect Number
Enhancement Number
Cause
  1. The shared memory parameter is invalid, for example -lruskips is not supported. 
  2. The input value used to increase a shared memory parameter is invalid. Shared memory input values cannot be:
  • Less than those already in use, or
  • Greater than supported limits for the OpenEdge version in use.
Resolution
  1. A limited subset of shared memory parameters can be increased online. Refer to Article  What is proutil <dbname> -C  increaseto?   
  2. Review the current shared-memory values then adjust the shared memory parameter value accordingly:  PROMON > Option 6.  Shared resources
.  

 
Workaround
Notes
Last Modified Date11/20/2020 7:13 AM
Attachment 
Files
Disclaimer The origins of the information on this site may be internal or external to Progress Software Corporation (“Progress”). Progress Software Corporation makes all reasonable efforts to verify this information. However, the information provided is for your information only. Progress Software Corporation makes no explicit or implied claims to the validity of this information.

Any sample code provided on this site is not supported under any Progress support program or service. The sample code is provided on an "AS IS" basis. Progress makes no warranties, express or implied, and disclaims all implied warranties including, without limitation, the implied warranties of merchantability or of fitness for a particular purpose. The entire risk arising out of the use or performance of the sample code is borne by the user. In no event shall Progress, its employees, or anyone else involved in the creation, production, or delivery of the code be liable for any damages whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business information, or other pecuniary loss) arising out of the use of or inability to use the sample code, even if Progress has been advised of the possibility of such damages.